BS4D: Ventilation Strategies

windowsLet me start off with one quick key point to keep in mind, ventilation is not about energy savings; rather it is about the building occupant’s health, safety, & comfort.

Yes, the choices one makes can play a factor on energy costs & savings but that should not be ones primary focus when choosing a strategy. In this article we are going to focus on the main reason for ventilation & that is breathing & removing some contaminants. As for makeup air & spot ventilation (Kitchen Exhaust / Bathroom Exhaust / Dryer Exhaust), that will have to wait for another day, though we will briefly touch on a few aspects…

3 methods / 5 strategies:

Basically there are three main ways one can choose to ventilate a house.  The first one has worked fine throughout the centuries & is one where you are an “Active” participant; you open a window, leave a door open, run a swamp cooler, whole house fan, etc… The second one involves you doing nothing but being “Passive”; letting stack effect, wind or pressure imbalances introduce “fresh” air to the house through your basement, crawl space, attic and other associated cracks & crevices.  The third type is using a “Mechanical” system which typically falls under an Exhaust only, Pressurize only, or a balanced strategy.

historyAs it relates to ventilation, 62.2.xx is considered the standard to follow. Many municipalities are currently using the 2007 or 2010 version (aka xx = .07 or .10). While some groups like using BPI’s standard aka 62.89, it really is outdated & not even recognized by ASHRAE anymore (thus the .2). No matter your feelings on the subject, there are pros & cons to how the numbers are arrived at that impact not only costs but the primary purpose of ventilation – health, safety, and comfort.

Active:

While this has worked well throughout the centuries – during certain time of the year, changes in building practices, allergies, acceptable comfort levels, other conditions and factors may not make this conducive to one just opening up the windows or turning on the whole house fan anymore. Unfortunately when this happens you are now stuck in “Passive” &/or Exhaust Only mode.

legalMany people ask, what’s wrong with / why can’t people just open up a window? Well nothing really is wrong with it, but then again I am not a code official or engineer who has to look at what the majority do or need based on the changing landscape (remember one change affects other items).

Passive:

As mentioned in “Does my house need to breathe” article, do you really think that air infiltrating through many small holes located in your garage, attic, crawl space… with no opportunity to filter or condition it as it is picking up toxic substances from not only the building materials it passes through (e.g. formaldehyde, asbestos, mold, lead…) but also from what is around it like animal droppings is such a good idea? Well good, I don’t think so either.

Just in case, here is where some of your "fresh" air comes from

Just in case, here is where some of your “fresh” air comes from

historyJust how much “fresh” air is needed? Break out the popcorn & welcome to Building Science Fight Club night as opinions vary across the spectrum. While we have beat up on BPI enough about their standard, ASHRAE’s has a few issues itself. 62.2.10 calls for 7.5 CFM per person plus 1 per 100 SF of building ((Number of bedrooms +1) x 7.5 + CFA/100). Many of us consider that overkill especially with most people not being there 24×7, using exhaust fans, constantly going in & out of the house, etc… In this case we simply make sure the system installed can handle the total & dial it back.

Recently .13 came out which calls for the above with one small little tweak – instead of 1 CFM per 100 SF, they want 3. Sorry folks in case you for forgot the house doesn’t need to breathe, just the people & pets. If you think that .10 was excessive, wait till you crunch these numbers on a McMansion. Yeah nothing like taking a few steps back. For more on this & other ventilation issues you might want to check out Joe Lstiburek’s recent piece on unintended consequences.

So how do we fine tune ours – we listen & observe. How active are they, in good shape, pets,  house plants, smokers, spend a lot of time indoors or out & about? These all play a factor in not only finding what works for them but balancing it with everything else. In the end we take our best guess & set a timer accordingly. Now if we get a stuffy feeling call we can or even the homeowner can increase the amount of time it is run.

Hopefully soon the market will release a unit capable of turning on or off based on carbon dioxide &/or other items making these time & cubic feet arguments & measurements meaningless.

Mechanical – Pressurize Only:

This system is common in hot (especially humid) climates and relies on over pressurizing ones house by bringing in fresh air from a central location. This is generally accomplished by one of the following two methods; adding an air intake on your forced air system from outside or by cutting a hole in your walls & installing a fan to push outside air in.

  • Relatively inexpensive and simple to install
  • The only strategy that might help reduce radon intrusion (see below)
  • It can help reduce / prevent back drafting of combustion appliances (which shouldn’t be in your house anyways) when the Forced Air or Fan is running (if it is off it won’t help as they require a mechanical damper)
  • Both systems can allow filtering of pollen and dust from the outside air if setup that way
  • Both systems can allow for dehumidification to happen before it enters (cost goes up) – if you live in a coastal or humid area, you will probably need it
  • Can cause major moisture issues in colder climates (forcing humid air into a cavity where the dew point can easily be reached)  causing condensation & rot
  • It will increase heating and cooling costs compared to others
  • It is hard on the forced air system (especially when tied into it)
  • You have no control over where the exhaust air goes
legalAs mentioned in “Build Radon Out” while stack effect or having less pressure inside the house can contribute to Radon entering, that isn’t the only factor involved. A pressurized system can help prevent it from intruding but will not exhaust it. An exhaust only system may exhaust some but when you consider it is pulling a vacuum it will probably be increasing the amount in the house. A balanced system doesn’t block it nor encourage it’s entry, but it also is not designed to help ensure it is exhausted. This is one reason why it doesn’t matter what type of house you have you should test regularly & install a passive system when you build or remodel (especially in Zone 1 & 2).

Mechanical – Exhaust Only:

An exhaust only system is more popular in the more northern (drier) climates and works by depressurizing your house forcing fresh air to enter via all those cracks & crevices. This is generally accomplished via a bathroom fan running 24×7 or for a set period.

  • Relatively inexpensive and simple to install
  • Remember how radon enters? Nothing like creating an environment to make it easier… or pulling air in all the time from the garage, attic & crawl
  • It will increase heating and cooling costs compared to others
  • If you have a naturally or atmospherically drafted appliance inside, watch out as not only are you fighting for the same air… back drafting & spillage chances are higher
  • Not a wise choice in hot humid climates as you are pulling hot humid air into a cavity where the dew point can be reached
fresh-air-from-fiberglass

Believe it or not, that actually started off as “pink” insulation – yep it can only filter so long, which doesn’t take into account the loss of R-Value or how much bypassed the insulation via the gaps

historyVery rarely will you find a Pressure or Exhaust only type of system in a commercial setting. The most notable exceptions are for “hot” rooms & “clean” rooms. In a “hot” room setting the object is to trap any pathogens or other such material inside the area thus preventing it from getting out and hurting unprotected individuals. In a “clean” room the object is to make sure any dirt or other such items can’t make it into the room from the outside. In many ways this is pretty similar to houses except for the immense amount of mechanical knowledge used to pull it off properly.

Mechanical – Balanced:

A balanced system is one designed to let as much fresh air in as is it exhausts in a controlled fashion. While there are numerous ways of accomplishing this, the most common method used involves a unit called an ERV or HRV. Both types of units are similar in nature that the object is to take the stale yucky but nicely conditioned air from inside & use it to precondition the incoming fresh air. We will cover more on this subject at a later time.

  • This is the only type of strategy appropriate for all climates
  • Most units come with a HEPA style or rated filter and are recommended by the American Lung Association for a “healthy” house
  • Cost & complexity can be a factor depending on what you want to accomplish & how you wish to do it
  • This can increase heating and cooling costs, though some system setups can lower them (sorry you will just have to check back later)
  • Finding knowledgeable contractors & designers can be an issue in some areas
  • You may require freeze / frost protection in cold climates
  • No matter if you get an ERV or HRV, indoor humidity levels can become a big factor in humid climates & may require a dehumidifier be added.

erv-hrv-diagram

Related posts:

Resistance is futile - Conversion Factors
Electrical FAQ: Off the wall questions...
FAQ: Do I really need to test smoke detector monthly?
FAQ Insulation Values & Comparisons - Metric and Imperial
FAQ: Do I need to change my HVAC filter monthly?
BS4D: Mold
BS4D: Radiant Barriers
2021 IECC Insulation vrs PHIUS 2.0 & other programs
  •  Tweet
  •  
  •  
  •  
  •  
  •  

Filed Under: FAQ's, Acronym’s, & Terminology June 20, 2013 By SLS 4 Comments

Featured Posts

January - Mid Winter Maintenance Checklist

Welcome to the start of a New Year, and the first full month of winter. This is the time of the year when many individuals try to wipe the slate ...

Read More

Preventing or fixing frozen water pipes

Updated: This article was originally posted in early 2010 after the Alabama Department of Health issued the following warning via press release: Prolonged period of cold weather ahead prompts warnings to ...

Read More

BS4D: Saving on Heating Related Energy Costs

For the bulk of the year, energy costs are not a big concern to many and instead most calls relate to comfort, safety or health issues. We are now starting ...

Read More

FAQ - Do I need storm doors or windows?

As the weather starts turning colder many start wondering - should I replace my windows, get a storm door, install storm windows, or??? Shoot I live in an area governed ...

Read More

Common Sense Building: Build Radon Out

Common Sense Building: Build Radon Out

As many of you probably already know, January is National Radon Month. Just like CO, it is an odorless & tasteless gas; however, unlike CO there are no warning signs ...

Read More

FAQ: Ceiling fan direction - summer & winter

One of the biggest questions out there is which direction should my fan be running and how can I tell. You look at the switch and realize it isn't any ...

Read More

FAQ on Duct Cleaning: All Hype or Worthy Expense?

It must be spring time... I got the following in the mail just the other day: 5 different ads all for duct cleaning. With allergy season starting along with my ...

Read More

Random Glossary term

  • Charrette

    Let me start off with one quick key point to keep in mind, ventilation is not about energy savings; rather it is about the building occupant’s health, safety, & comfort. Yes, the choices one makes can play a factor on energy costs & savings but that should not be ones primary focus when choosing a […]

The HTRC - Copyright © 2006–2021 by TheHTRC.com & SLS Construction & Building Solutions LLC http://SLS-Construction.com