The HTRC

The Homeowners & Trades Resource Center

Brought to you by:

You are here: Home / Building Codes / Energy Code Basics: Avoiding the most common fail

Energy Code Basics: Avoiding the most common fail

No one likes to fail a building inspection especially when you get dinged a penalty from the Building Department for it. Not only are you out the fee & time you spent there, but it can leave the homeowner or General Contractor wondering about your work.

So what is the biggest failure? Duct leakage or the air leakage test – nope because you have to have that sorted out before you call out the inspector in most cases. Insulation – while this can be an issue for some it generally isn’t an issue for most as most inspectors just make sure it is installed & what the R-Value is. Air-Sealing – with most builders & the trades understanding what is required this rarely is an issue. So what’s left…

The Attic Hatch & Weather Stripping:

Seriously? Yes folks, the biggest issue is the one that even the greenest or most jaded inspector can easily check at final, is there weather stripping around the attic hatch and secondly is it insulated?

R402.2.4 Access hatches and doors. Access doors from conditioned spaces to unconditioned spaces such as attics and crawl spaces shall be weatherstripped and insulated to a level equivalent to the insulation on the surrounding surfaces…

That first one is one of the most overlooked items by most GC’s and they get dinged as they are generally worrying about 1001 other little details to get the project completed that are at eye-level. That is one reason why one of the first items we check for those just doing DET testing is that as it is so often overlooked.

Insulating the Hatch:

In our area hatches need to be insulated to R49 so most insulators simply tape 5 layers of 2″ foam (R10 x 5 = R50) to the drywall hatch as shown. One item I have seen with this is if the foam becomes dislodged so I would recommend that the tap also extend over the drywall. (If you are in climate zone 2 or 3 – you only need 4 pieces while those in CZ1 only need 3)

With that said if you are looking for real performance I would not suggest this style. The reason is if you look at the two pictures explain how you would get a tight fix with no gaps… I much prefer the lid style which becomes almost mandatory if you have an access ladder.

How about doorways between living area & my attic?

I don’t have a hatch but rather an actual door – do I need to insulate it to… In short no, there is an exception that states that a “vertical door” going from conditioned to unconditioned spaces must meet the Fenestration requirements for an exterior door. Please note that even though a solid wood interior door may meet the fenestration requirement it must still be fully weather-stripped. Shoot even if the building inspector misses it, your customers won’t. I would even recommend self closing hinges especially if you have fuel burning appliance located in the attic.

So want to avoid the biggest failure – don’t forget to look up & don’t just assume that your insulator remembered to install that weather-stripping.

Related posts:

BS4D: Energy Codes
Energy Code Basics: Duct Testing - 4% or doesn't matter?
Alabama Energy Code Updates: 38 days & counting
Illinois & the Fight over the ERI Path
Monday Musings: 2021 IECC Part 2
First Look - The 2015 IRC Changes
Energy Code Basics: 3 Key Terms & Compliance Paths
2018 IECC - 2nd Public Comment Period Open
  •  Tweet
  •  
  •  
  •  
  •  
  •  

Filed Under: Building Codes July 13, 2018 By SLS Leave a Comment

Featured Posts

January - Mid Winter Maintenance Checklist

Welcome to the start of a New Year, and the first full month of winter. This is the time of the year when many individuals try to wipe the slate ...

Read More

Preventing or fixing frozen water pipes

Updated: This article was originally posted in early 2010 after the Alabama Department of Health issued the following warning via press release: Prolonged period of cold weather ahead prompts warnings to ...

Read More

BS4D: Saving on Heating Related Energy Costs

For the bulk of the year, energy costs are not a big concern to many and instead most calls relate to comfort, safety or health issues. We are now starting ...

Read More

FAQ - Do I need storm doors or windows?

As the weather starts turning colder many start wondering - should I replace my windows, get a storm door, install storm windows, or??? Shoot I live in an area governed ...

Read More

Common Sense Building: Build Radon Out

Common Sense Building: Build Radon Out

As many of you probably already know, January is National Radon Month. Just like CO, it is an odorless & tasteless gas; however, unlike CO there are no warning signs ...

Read More

FAQ: Ceiling fan direction - summer & winter

One of the biggest questions out there is which direction should my fan be running and how can I tell. You look at the switch and realize it isn't any ...

Read More

FAQ on Duct Cleaning: All Hype or Worthy Expense?

It must be spring time... I got the following in the mail just the other day: 5 different ads all for duct cleaning. With allergy season starting along with my ...

Read More

Random Glossary term

  • Zone

    No one likes to fail a building inspection especially when you get dinged a penalty from the Building Department for it. Not only are you out the fee & time you spent there, but it can leave the homeowner or General Contractor wondering about your work. So what is the biggest failure? Duct leakage or […]

The HTRC - Copyright © 2006–2021 by TheHTRC.com & SLS Construction & Building Solutions LLC http://SLS-Construction.com